Related Experiment Video
Updated: Aug 14, 2026

A Method for Systematic Electrochemical and Electrophysiological Evaluation of Neural Recording Electrodes
Published on: March 3, 2014
An investigation into the electrical ablation technique and a method of electrode assessment
Abstract:
Ablative techniques, using standard defibrillators and commonly available cardiac catheters, have been applied to the His bundle and bypass tracts for the management of arrhythmias. We have done in vitro studies of the physical effects of these high energy electrical impulses delivered via different pacing electrodes. Unipolar impulses of 10 to 400 joules were delivered via three U.S.C.I. bipolar electrodes and three Vitatron Helifix electrodes immersed in Ringer's solution. The effects were recorded on 35 mm still film, video tape, and high speed cine film. Pressure, voltage, and current were measured. The U.S.C.I. bipolar electrodes and the Vitatron Helifix electrodes safely withstood repeated delivery of 400-joule impulses which produced similar flash shapes. Each took the form of an incandescent, spherical "fire-ball" centered around the exposed electrode surface. The mean diameters of the "fire-ball" for 10 to 400 J using the U.S.C.I. electrodes were 5-24 mm and 3-20 mm for the Helifix catheter electrodes. Peak pressure excursions of over an atmosphere were observed 3 cm from the electrode tips. Higher pressures, lower voltages, and larger currents occurred using the U.S.C.I. pacing lead. The simple, 35 mm time exposure technique showed that at low energies the flashes appeared to emerge in a retrograde manner from the U.S.C.I. catheters and more distally from the Helifix electrode. This suggested that the latter might be more effective with lower energy impulses. It is concluded that lower energies should be used to take full advantage of the active fixation electrode.
Related Concept Videos
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Interfacial Electrochemical Methods: Overview
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...