Relationships between patient size, dose and image noise under automatic tube current modulation systems
S Sookpeng1, C J Martin, D J Gentle
1Health Physics, Gartnavel Royal Hospital, 1055 Great Western Road, Glasgow G12 0XH, UK. Department of Clinical Physics, University of Glasgow, Glasgow G12 8QQ, UK.
Different automatic tube current modulation (ATCM) systems impact patient CT dose. Toshiba and GE scanners show higher doses for larger patients, while Philips and Siemens offer more consistent results, optimizing patient dose.
Area of Science:
- Medical Imaging
- Radiological Physics
Background:
- Automatic tube current modulation (ATCM) is standard in CT imaging.
- Manufacturer-specific ATCM principles affect image noise and patient dose.
- Understanding these differences is crucial for CT dose optimization.
Purpose of the Study:
- To survey and analyze CT patient doses across different manufacturers.
- To investigate the relationship between patient size, ATCM, and image noise.
- To compare dose optimization strategies among leading CT scanner brands.
Main Methods:
- Surveyed CT patient doses on 14 scanners from four manufacturers.
- Analyzed patient cross-sectional area, ATCM settings, and image noise using custom software.
- Compared dose and modulation behaviors across different scanner models.
Main Results:
- Toshiba and GE scanners maintained consistent noise but showed dose increases with patient size.
- Philips and Siemens scanners exhibited less dependence on patient size for tube current, resulting in lower doses for larger patients.
- Image noise was found to be more dependent on patient size in Philips and Siemens systems.
Conclusions:
- CT scanner manufacturer significantly influences patient dose optimization via ATCM.
- Toshiba/GE approaches can lead to substantially higher doses for larger patients compared to Philips/Siemens.
- Tailoring ATCM knowledge to specific scanner models is essential for effective CT dose reduction.