Decreasing bacterial cross-contamination with a pulsating nasal irrigation device
Mark Keen1, Philip G Chen, Peter-John Wormald
1Department of Surgery-Otorhinolaryngology, Head and Neck Surgery, University of Adelaide, Adelaide, Australia.
Nasal irrigation bottles can become contaminated, but the Sinugator device showed no cross-contamination between patients and their devices. This study assessed bacterial growth in pulsating nasal wash bottles after endoscopic sinus surgery.
Area of Science:
- Otolaryngology
- Microbiology
Background:
- Nasal irrigation is common for post-endoscopic sinus surgery (ESS) patients.
- Concerns exist regarding the contamination of nasal irrigation bottles.
- The Sinugator cordless pulsating nasal wash device features a unidirectional flow design.
Purpose of the Study:
- To determine the incidence of cross-contamination with the Sinugator pulsating nasal irrigation device.
- To compare contamination rates between the Sinugator and traditional squeeze bottles.
Main Methods:
- Eleven post-ESS patients used the Sinugator device three times daily.
- Nasal swabs and device reservoir swabs were collected for bacterial culture.
- Cultures were analyzed for organism presence at initial and follow-up visits.
Main Results:
- A 45% contamination rate was observed in the irrigation bottles.
- Common organisms cultured included coliforms and Staphylococcus aureus.
- No concomitant organisms were found in both nasal cultures and bottles for any patient.
Conclusions:
- Positive bacterial cultures were found in patients and their Sinugator bottles.
- The Sinugator device's design appears to prevent cross-contamination between patients and bottles.
- The unidirectional flow may mitigate backwash, reducing the risk of organism transfer.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Hand hygiene
Hand washing...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...