CE-ESI-MS for bottom-up proteomics: Advances in separation, interfacing and applications
Anthonius A M Heemskerk1, André M Deelder1, Oleg A Mayboroda1
1Center for Proteomics and Metabolomics, Leiden University Medical Center, Albinusdreef 2, 2300, RC, Leiden, The Netherlands.
Mass Spectrometry Reviews
|May 24, 2014
Summary
Sensitive capillary electrophoresis-electrospray-mass spectrometry (CE-ESI-MS) methods are crucial for analyzing peptides and protein digests. This review covers new hyphenation strategies and technical aspects for bottom-up proteomics.
Area of Science:
- Analytical Chemistry
- Proteomics
- Biochemistry
Background:
- Capillary Electrophoresis-Electrospray-Mass Spectrometry (CE-ESI-MS) has re-emerged as a powerful technique for peptide and protein digest analysis.
- Recent advancements in hyphenation strategies have significantly enhanced its separation power and sensitivity.
- The period from 2009 to the present has seen notable developments, particularly with co-axial sheath liquid interfaces.
Purpose of the Study:
- To review newly developed hyphenation strategies for CE-ESI-MS.
- To discuss applications of CE-ESI-MS in bottom-up proteomics.
- To provide a comprehensive overview of method development aspects for CE-ESI-MS in proteomics.
Main Methods:
- Discussion of newly developed hyphenation strategies for CE-ESI-MS.
- Analysis of applications in bottom-up proteomics using CE-ESI-MS with co-axial sheath liquid.
- Detailed examination of technical aspects including background electrolyte choice, capillary coating, and loading methods.
Main Results:
- CE-ESI-MS offers high separation power and sensitivity for peptide and protein digest analysis.
- Co-axial sheath liquid interfaces have been instrumental in recent advancements.
- Modeling of peptide migration in capillary electrophoresis is feasible due to the simple separation process.
Conclusions:
- CE-ESI-MS is a highly effective technique for bottom-up proteomics.
- Careful consideration of method development parameters (electrolyte, coating, loading) is crucial for optimal results.
- Future developments are expected to further enhance the capabilities of CE-ESI-MS in proteomics.
Related Concept Videos
Proteomics
7.5K
A proteome is the entire set of proteins that a cell type produces. We can study proteomes using the knowledge of genomes because genes code for mRNAs, and the mRNAs encode proteins. Although mRNA analysis is a step in the right direction, not all mRNAs are translated into proteins.
Proteomics is the study of proteomes' function. It involves the large-scale systematic study of the proteome to denote the protein complement expressed by a genome. Scientist Mark Wilkins coined the term...
Proteomics is the study of proteomes' function. It involves the large-scale systematic study of the proteome to denote the protein complement expressed by a genome. Scientist Mark Wilkins coined the term...
7.5K
Electrospray Ionization (ESI) Mass Spectrometry
2.6K
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.6K