Related Experiment Video
Updated: Apr 26, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Preparation of Monolithic Capillary Chromatographic Columns Using Supercritical Fluid as a Porogen Solvent
Michał Szumski1, Bogusław Buszewski1
1Faculty of Chemistry, Department of Environmental Chemistry and Bioanalytics, Nicolaus Copernicus University, Gagarina 7, 87-100 Toruń, Poland.
Abstract:
Monolithic polymeric beds were synthesized in fused silica capillaries using either trimethylolpropane trimethacrylate (TRIM) or a mixture of butyl methacrylate (BMA) with ethylene glycol dimethacrylate (EDMA) as monomers. Carbon dioxide at temperature and pressure conditions above its critical values was used as a porogen solvent. The purpose of using the supercritical carbon dioxide was to have the possibility of changing the solvation power (and thus the porosity of the resulting monolith) of the porogen by pressure and temperature changes instead of changing the porogen composition. The experiments were performed using a special setup consisting of a stainless steel high-pressure reactor to which the fused silica capillary was connected. The synthesized monoliths underwent liquid chromatographic evaluation. The polyTRIM capillary monoliths were characterized by different permeability, which depended on the pressure of the synthesis. BMA/EDMA columns were applied for separation of alkylbenzenes and a model mixture of proteins.
More Related Videos
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Principles Of Column Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process