Occupational exposure to 131I-a case study
Maarit Muikku1, Jussi Huikari, Helinä Korpela
1*STUK-Radiation and Nuclear Safety Authority, P.O. Box 14, FIN-00881, Helsinki, Finland.
A laboratory technician experienced significant radioactive iodine-131 contamination on their hand and thyroid gland during radiopharmaceutical preparation. Prompt decontamination limited long-term skin damage, but thyroid uptake and minor chromosomal aberrations were observed.
Area of Science:
- Occupational Health
- Radiopharmaceutical Safety
- Nuclear Medicine
Background:
- Accidental radioactive contamination poses risks in radiopharmaceutical manufacturing.
- Iodine-131 (I) is used in thyroid carcinoma treatment, necessitating strict handling protocols.
Purpose of the Study:
- To document and analyze a case of accidental Iodine-131 contamination in a laboratory setting.
- To assess the effectiveness of immediate decontamination procedures and evaluate the resulting radiation doses.
Main Methods:
- Routine monitoring and surface contamination measurements.
- Whole body counting for internal contamination assessment.
- Dose estimation for skin and thyroid gland.
- Cytogenetic analysis of peripheral lymphocytes.
Main Results:
- Estimated Iodine-131 activity on hand: 12 MBq, resulting in a superficial skin dose of 33 Gy.
- Thyroid gland uptake detected, leading to an estimated thyroid dose of 430 mGy.
- Transient skin effects (dryness, desquamation) and a slight elevation in chromosomal aberrations were noted.
Conclusions:
- Despite initial heavy contamination and high superficial skin dose, prompt action prevented severe long-term skin damage.
- Internalization of Iodine-131 to the thyroid gland occurred, highlighting the importance of comprehensive monitoring.
- Cytogenetic analysis suggests a biological response to the radiation exposure, warranting continued observation.
More Related Videos
08:23An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
07:28An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Related Concept Videos
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...