Dark-field transmission electron microscopy and the Debye-Waller factor of graphene

Brian Shevitski1,2, Matthew Mecklenburg1,2,3, William A Hubbard1,2

  • 1Department of Physics and Astronomy, University of California, Los Angeles, California, 90095, USA.

Physical Review. B, Condensed Matter and Materials Physics
|September 23, 2014
PubMed

Related Concept Videos

Transmission Electron Microscopy01:15

Transmission Electron Microscopy

In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
6.0K
The de Broglie Wavelength02:32

The de Broglie Wavelength

In the macroscopic world, objects that are large enough to be seen by the naked eye follow the rules of classical physics. A billiard ball moving on a table will behave like a particle; it will continue traveling in a straight line unless it collides with another ball, or it is acted on by some other force, such as friction. The ball has a well-defined position and velocity or well-defined momentum, p = mv, which is defined by mass m and velocity v at any given moment. This is the typical...
25.5K
Debye–Huckel–Onsager Conductance Equation01:28

Debye–Huckel–Onsager Conductance Equation

The Debye-Hückel-Onsager equation is a cornerstone of physical chemistry, providing a method to determine the molar conductance (Λm) and molar conductance at infinite dilution (Λ°m) for uni-univalent electrolytes.Uni-univalent electrolytes are electrolytes that dissociate in solution to produce one cation with a +1 charge and one anion with a –1 charge per formula unit.This equation addresses two crucial phenomena: the asymmetry effect and the electrophoretic effect.
279
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
11.6K