Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Conduction abnormality and arrhythmia after transcatheter closure of atrial septal defect
Monika Komar1, Tadeusz Przewłocki, Maria Olszowska
1Department of Cardiac and Vascular Diseases, Institute of Cardiology, Jagiellonian University.
Background:
The aim of this study was to prospectively perform ambulatory 24-h ECG monitoring to assess the effects of transcatheter closure of atrial septal defect (ASD).
Methods And Results:
A total of 235 consecutive subjects (female, n=163; male, n=72; age, 44.6±14.4 years) were enrolled in the study, who were due undergo ASD closure. Holter monitoring was performed before procedure and at 1, 6 and 12 months of follow-up. During the procedure transient supraventricular arrhythmia occurred in 8 patients (3.4%), and bradycardia in 3 (1.3%). In 3 patients (1.3%) an episode of atrial fibrillation occurred in the first hour after the procedure. In 8 patients (3.4%) transient first-degree atrioventricular block was noted. A significant increase in number of supraventricular extrasystoles (SVES)/24 h was noted 1 month after the procedure (P<0.001). On multiple forward stepwise regression analysis, device size and fluoroscopy time had an influence on increase in number of SVES seen 1 month after the procedure (P<0.001).
Conclusions:
Transcatheter closure of ASD is associated with a transient increase in supraventricular premature beats and a small risk of conduction abnormalities and paroxysmal atrial fibrillation in early follow-up. Transcatheter closure of ASD does not reduce arrhythmia that appears prior to ASD closure. Larger device size and longer procedure time are associated with increased risk of supraventricular arrhythmia on early follow-up.
More Related Videos
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Mechanism of Cardiac Arrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...