Evaluation of cardiovascular changes in dogs administered three positive controls using jacketed external
John J Kremer1, Andrew J Bills1, Nathanael J Hanke1
1Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704-2523, USA.
Introduction:
Nonclinical safety studies are increasingly incorporating cardiac safety endpoints to discover potential cardiovascular liabilities. This trend for more thorough cardiovascular nonclinical safety evaluation is prudent given the high attrition rate of potential therapeutics due to unexpected cardiovascular liabilities discovered in late-stage clinical trials or post-market approval. In particular, the causal relationship of blood pressure changes that lead to risk of major adverse cardiac events suggests hemodynamic changes should be critically evaluated in preclinical studies of novel therapeutics.
Methods:
Jacketed external telemetry with an implanted miniature blood pressure transmitter (JET-BP) was used to characterize the tolerability, functionality, and sensitivity of this study design in dogs. Thirty-six male or female beagles (n=6 dogs/sex/group) were administered vehicle control (reverse osmosis water) or etilefrine (1, 10mg/kg), sotalol (3, 30mg/kg), and hydralazine (1, 10mg/kg) on separate days. Telemetry data were evaluated for positive control article-related changes and retrospective power analysis was also completed. Animals were evaluated for instrumentation-related changes in clinical and anatomic pathology endpoints.
Results:
All three positive controls elicited the expected pharmacologic responses that were statistically different at high and low doses. Retrospective power analysis confirmed this study design was able to statistically differentiate minor (approximately 5 to 15%) changes in electrocardiography and blood pressure values. This study also demonstrated the potential advantages of combining cardiovascular data across sex when the test article exposure and pharmacodynamics were consistent. Data collection using miniature telemetry blood pressure transmitters did not result in anatomic or clinical pathology findings that would prevent their use in general toxicology studies.
Discussion:
This characterization study indicates that JET-BP in dogs offers a scientifically-robust method to evaluate novel therapeutics for potential cardiovascular liabilities.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure