Scanning balanced-path homodyne I/Q-interferometer scheme and its applications
Optics Letters
|June 2, 2015
Summary
A novel scanning interferometer scheme improves vibration rejection by 11 dB, enabling high-sensitivity phase and amplitude measurements for complex sample analysis, such as protein biochips.
Area of Science:
- Optics and Photonics
- Biomedical Engineering
- Analytical Chemistry
Background:
- Heterodyne interferometers are susceptible to environmental vibrations, limiting measurement sensitivity and stability.
- Existing scanning interferometers face challenges in achieving high-speed, high-precision measurements for complex samples.
Purpose of the Study:
- To adapt the balanced-path scheme for a scanning homodyne I/Q-interferometer.
- To enhance common vibration rejection for improved measurement performance.
- To demonstrate the utility of the improved interferometer for complex sample analysis.
Main Methods:
- Implementation of the balanced-path scheme in a scanning homodyne I/Q-interferometer.
- Comparative analysis of vibration rejection against the traditional heterodyne scheme.
- Application of the developed interferometer for imaging protein biochip samples.
Main Results:
- An 11-dB improvement in common vibration rejection was achieved compared to the heterodyne scheme.
- High sensitivity and stability in phase and amplitude measurements were demonstrated.
- Successful acquisition of phase and amplitude images for protein biochip samples was performed.
Conclusions:
- The proposed scanning interferometer scheme offers superior vibration rejection, enabling high-performance measurements.
- This advanced interferometer is highly effective for diagnosing samples requiring intricate analysis, including homogeneity and concentration-dependent phase differences.
- The application to protein biochips highlights its potential in biomedical diagnostics and material characterization.
Related Concept Videos
Interference and Diffraction
54.7K
Interference is a characteristic phenomenon exhibited by waves. When two electromagnetic waves interact with their peaks and troughs coinciding, a resulting wave with enhanced amplitude is produced. This is known as constructive interference. In this case, the two waves interacting are in phase with each other.
54.7K
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
2.3K
Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single...
2.3K
Electronic Distance Measuring Instruments
695
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over...
695
Infrared (IR) Spectroscopy: Overview
7.5K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
7.5K
Raman Spectroscopy Instrumentation: Overview
1.9K
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.9K
Phase Contrast and Differential Interference Contrast Microscopy
15.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
15.2K