Distance stereotesting using vision test charts for intermittent exotropia.
Noriko Nishikawa1, Satoshi Ishiko2, Ikuko Yamaga1
1Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Japan.
Clinical Ophthalmology (Auckland, N.Z.)
|September 9, 2015
Summary
The System Chart SC-1600 Pola (SC) offers a more sensitive measure of distance stereoacuity for evaluating intermittent exotropia (IXT). This objective stereoacuity assessment correlates with ocular alignment control in children with IXT.
Area of Science:
- Ophthalmology
- Vision Science
- Pediatric Ophthalmology
Background:
- Intermittent exotropia (IXT) is a common childhood strabismus characterized by outward deviation of the eyes.
- Accurate assessment of stereoacuity is crucial for evaluating the severity and control of IXT.
- Current methods for measuring distance stereoacuity may have limitations in objectively quantifying IXT control.
Purpose of the Study:
- To evaluate the effectiveness of the System Chart SC-1600 Pola (SC) test in assessing distance stereoacuity.
- To determine if the SC test can serve as an objective measure for evaluating intermittent exotropia (IXT).
- To compare the SC test's performance against established stereotests and ocular alignment scores.
Main Methods:
- Stereoacuity was measured in 28 children with IXT and 25 controls using the SC test and the distance Randot stereotest.
- Near stereoacuity was assessed with the Titmus stereotest.
- Ocular alignment control was quantified using the revised Newcastle Control Score (NCS), and correlations were analyzed using Spearman's test.
Main Results:
- The SC test demonstrated significantly better distance stereoacuity compared to the distance Randot stereotest in both IXT patients and controls (P<0.001).
- A significant positive correlation was found between SC test scores and both distance and total NCS scores (r s=0.49, P=0.004).
- No significant correlation was observed between NCS scores and the distance Randot or Titmus stereotest scores.
Conclusions:
- Distance stereoacuity measured by the SC test appears to be a sensitive and objective indicator of IXT control.
- The SC test shows promise as a valuable tool for clinical assessment of intermittent exotropia.
- The SC test's correlation with NCS suggests its utility in objectively monitoring treatment outcomes for IXT.