Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

14.8K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.8K
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

1.9K
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
1.9K
Photoluminescence: Fluorescence and Phosphorescence01:23

Photoluminescence: Fluorescence and Phosphorescence

5.1K
Photoluminescence is a process where a molecule absorbs light energy and re-emits it in the form of light. This phenomenon occurs when a substance absorbs photons, promoting its electrons to higher energy level excited states, followed by a relaxation process in which the electrons return to their original ground state energy levels and emit light. Photoluminescence is widely observed in various materials, including semiconductors, and organic and inorganic compounds.
A pair of electrons in a...
5.1K
Variables Affecting Phosphorescence and Fluorescence01:26

Variables Affecting Phosphorescence and Fluorescence

2.3K
Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
2.3K
Protein Dynamics in Living Cells01:19

Protein Dynamics in Living Cells

2.8K
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

SRM: A Source-Reprojection Module for Cross-Day sEMG Gesture Recognition.

Sensors (Basel, Switzerland)·2026
Same author

Development and preliminary clinical application of a time-resolved fluoroimmunoassay for anti-rituximab antibodies in membranous nephropathy.

Bioanalysis·2026
Same author

Innovative Nonwoven Fireproof Composite Felt from Recycled Waste Polyester Fibers.

Langmuir : the ACS journal of surfaces and colloids·2026
Same author

Osteogenic promotion by naringin through the PI3K/AKT/mTOR pathway-mediated activation of autophagy and inhibition of apoptosis.

Bone·2026
Same author

Endovascular Treatment Versus Medical Management in Patients with Large Vessel Occlusion and Pre-Stroke Disability: A Systematic Review and Meta-Analysis.

Turkish neurosurgery·2026
Same author

Detection of kanamycin residues in animal-derived foods using a homogeneous AlphaLICA immunoassay.

Analytical methods : advancing methods and applications·2026
Same journal

Gaussian-modulated continuous-variable quantum key distribution over 60 km fiber using an integrated silicon photonic receiver.

Optics letters·2026
Same journal

E2E-OCT: end-to-end joint learning model using optical coherence tomography images for vocal cord leukoplakia diagnosis.

Optics letters·2026
Same journal

Holographic generation of panoramic 3D scenes by concave ellipsoidal mirror reflection.

Optics letters·2026
Same journal

Dual-pilot phase recovery with pair-wise maximum-ratio combining for coherent PONs.

Optics letters·2026
Same journal

Mapping the whispering gallery modes of a CaF<sub>2</sub> disk resonator with half-tapered fibers to estimate the fundamental mode volume.

Optics letters·2026
Same journal

Quantitative estimation of deep-subwavelength scale via dark-field scattering axial energy concentration decay profiles.

Optics letters·2026
See all related articles

Related Experiment Video

Updated: Mar 31, 2026

Conducting Multiple Imaging Modes with One Fluorescence Microscope
08:32

Conducting Multiple Imaging Modes with One Fluorescence Microscope

Published on: October 28, 2018

10.4K

Virtual fluorescence emission difference microscopy based on photon reassignment.

Ye Ma, Cuifang Kuang, Yue Fang

    Optics Letters
    |October 16, 2015
    PubMed
    Summary
    This summary is machine-generated.

    Virtual fluorescence emission difference microscopy (vFED) offers high-resolution imaging with simplified equipment and faster speeds. This novel technique enhances resolution by over 27% compared to confocal microscopy.

    More Related Videos

    Simultaneous Multicolor Imaging of Biological Structures with Fluorescence Photoactivation Localization Microscopy
    12:51

    Simultaneous Multicolor Imaging of Biological Structures with Fluorescence Photoactivation Localization Microscopy

    Published on: December 9, 2013

    9.5K
    Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals
    07:34

    Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals

    Published on: August 22, 2019

    8.5K

    Related Experiment Videos

    Last Updated: Mar 31, 2026

    Conducting Multiple Imaging Modes with One Fluorescence Microscope
    08:32

    Conducting Multiple Imaging Modes with One Fluorescence Microscope

    Published on: October 28, 2018

    10.4K
    Simultaneous Multicolor Imaging of Biological Structures with Fluorescence Photoactivation Localization Microscopy
    12:51

    Simultaneous Multicolor Imaging of Biological Structures with Fluorescence Photoactivation Localization Microscopy

    Published on: December 9, 2013

    9.5K
    Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals
    07:34

    Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals

    Published on: August 22, 2019

    8.5K

    Area of Science:

    • Microscopy
    • Optical Imaging
    • Biophysics

    Background:

    • Traditional fluorescence microscopy techniques face limitations in resolution and speed.
    • Existing fluorescence emission difference (FED) systems require complex configurations.

    Purpose of the Study:

    • To introduce a novel high-resolution imaging method, virtual fluorescence emission difference microscopy (vFED).
    • To demonstrate the advantages of vFED in terms of resolution, speed, and equipment simplification.

    Main Methods:

    • Utilizing a doughnut-shaped illumination pattern and a detector array for sample scanning.
    • Implementing photon reassignment to generate matched solid and hollow point spread functions.
    • Calculating the difference between point spread functions to estimate sample spatial distribution.

    Main Results:

    • Achieved resolution enhancement of at least 27% compared to confocal microscopy with a point detector.
    • Obtained imaging resolution 1.8-2 fold higher than wide-field microscopy.
    • Eliminated image deformation by avoiding negative intensities during the subtraction process.

    Conclusions:

    • vFED provides a simplified and faster approach to high-resolution fluorescence imaging.
    • The method significantly enhances imaging resolution and improves image quality by preventing reconstruction artifacts.