Related Experiment Video
Updated: Mar 30, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea
Daniel J Levendowski1, Todd Morgan2, Philip Westbrook1
1Advanced Brain Monitoring Inc., Carlsbad, USA.
Background:
Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit.
Objective:
The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance.
Methods:
Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3.
Results:
Significant reductions in the mean overall and supine apnea indexes (p < 0.05), and the overall (p < 0.01) and supine (p < 0.05) apnea/hypopnea indexes were observed for both the titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p < 0.05) and supine (p < 0.01). Patients found their custom appliance was more comfortable than the titration appliance, but preferred the titration appliance to no therapy.
Conclusion:
The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...