A Tactile Automated Passive-Finger Stimulator TAPS
Published on: June 3, 2009
14.3K
Comparison of the Halstead-Reitan and Infrared Light Beam Finger Tappers
A R Coleman1, P J Moberg1, J D Ragland1
1University of Pennsylvania.
Assessment
|November 29, 2015
Summary
A new infrared light beam tapping device shows psychometric properties similar to traditional tests for evaluating psychomotor speed. This computer-mediated tool offers faster, reliable assessments of finger and foot tapping in healthy adults.
Area of Science:
- Neuroscience
- Psychology
- Human Movement Science
Background:
- Computer-mediated motor tests offer reliable psychomotor assessment.
- Infrared light beam technology enables novel computer-mediated tests.
- Psychometric properties of a new light beam tapping device require evaluation.
Purpose of the Study:
- To compare the psychometric properties of a new Light Beam Finger & Foot Tapping Device.
- To compare performance on the light beam device against the Halstead-Reitan Finger Tapping Test.
Main Methods:
- 16 men and 17 women completed both the Halstead-Reitan Finger Tapping Test and the Light Beam Finger Tapping Test.
- Performance metrics including speed, laterality, and rhythmicity were recorded.
- Correlations between the two tests were analyzed.
Main Results:
- The light beam test demonstrated psychometric properties comparable to the Halstead-Reitan test.
- Scores between the two finger tapping tests were moderately correlated.
- Participants achieved faster tapping speeds on the light beam device compared to the Halstead-Reitan test.
- Men outperformed women in tapping speed on both tests.
- Faster tapping was observed with the dominant hand on both devices.
- The light beam test also assessed synchronous and alternating tapping, and foot tapping, with moderate to high correlations between subtests.
Conclusions:
- The Light Beam Finger & Foot Tapping Device is a psychometrically sound tool for assessing psychomotor speed and rhythmicity.
- Its design may allow for more sensitive detection of subtle motor differences.
- The device offers a potentially more efficient and comprehensive assessment of tapping performance.
Related Concept Videos
IR Spectrometers
3.4K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
3.4K
IR Frequency Region: Fingerprint Region
2.3K
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...