Related Experiment Video
Updated: Mar 29, 2026

The Perinatal Asphyxiated Lamb Model: A Model for Newborn Resuscitation
Published on: August 15, 2018
Elective caesarean delivery adversely affects preductal oxygen saturation during birth transition
Vincenzo Zanardo1, Valentina Dal Cengio2, Matteo Parotto3
1Division of Perinatal Medicine, Policlinico Abano Terme, Abano Terme, Italy.
Objective:
To compare preductal oxygen saturation (SpO2), heart rate (HR) and cord blood pH after birth in healthy term neonates delivered by elective caesarean delivery (CD) and vaginal delivery (VD), managed according to 2010 Neonatal Resuscitation Guidelines.
Design:
In a prospective cohort study, sensors were placed on the right hand of the neonate.
Setting:
III level Maternity ward of the Department of Obstetrics and Gynaecology of Padua University, Padua, Italy.
Main Outcome Measures:
SpO2 and HR were recorded during the first 10 min after birth. Umbilical artery blood gas analysis was obtained immediately after delivery.
Patients:
We studied 60 newborn infants by elective CD and 60 by VD.
Results:
The SpO2 gradually significantly improved during the first 10 min of life (p<0.0001), with a trend towards a slower increase in caesarean-delivered neonates (p=0.09) (Friedman's two-way non-parametric analysis of variance (ANOVA)). Instead, HR varied during the first 10 min of life (p=0.001) without significant difference between the two delivery groups (p=0.41). Umbilical artery pH values were lower in VD (p=0.005). At 10th minute, elective CD had a significantly negative effect on SpO2 (ß=-2.44; 95% CI -4.52 to -0.36; p=0.02) with respect to VD. Conversely, at 10th minute, delivery mode had no statistically significant effect on HR (ß=0.33; 95% CI -9.39 to 10.01; p=0.95).
Conclusions:
In healthy term neonates, the SpO2 gradually improved during the first 10 min of life. At 10th minute, elective CD had a significantly negative effect on SpO2, but these changes did not result in an impaired HR pattern.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Transport in the Blood
Development of the Oral Microbiota