Related Experiment Video
Updated: Mar 21, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial
Daris Theerakulpisut1, Chanisa Chotipanich2
1Department of Radiology, Division of Nuclear Medicine, Khon Kaen University, Khon Kaen, Thailand.
Abstract:
Myocardial perfusion single photon emission computed tomography (SPECT) is a powerful test of evaluation for coronary artery disease, but subdiaphragmatic radiotracer activity often interferes with the interpretation of inferior wall findings. This study aims to evaluate the effectiveness of using software elimination of the subdiaphragmatic activity for the assessment of its efficacy in the correctness of image interpretation and the overall image quality of myocardial perfusion scintigraphy (MPS). MPS studies from January 2010 to October 2012 at our institution were reviewed. Thirty-two SPECT studies were included, all of which had significant subdiaphragmatic activity in the first scan and needed to be delayed to let the activity clear. Each scan was interpreted by using semiquantitative scoring in 17 segments according to the degree of radiotracer uptake. The first scan, which had interfering activity, was manipulated by masking out the unwanted activity with software native to our image processing software suite. The manipulated images were then compared with delayed images of the same patient, of which the subdiaphragmatic activity was spontaneously cleared with time. The first scan masked by software correlated with the delayed scan for myocardial regions supplied by the left circumflex (LCx) and right coronary artery (RCA), but not the left anterior descending (LAD). However, the quality of the masked scans was perceived by the observer to be better in terms of quality and ease of interpretation. Using software to mask out unwanted subdiaphragmatic activity has no detrimental effect on the interpretation of MPS images when compared with delayed scanning, but it can improve subjective scan quality and ease of interpretation.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...

