Voxel dosimetry: Comparison of MCNPX and DOSXYZnrc Monte Carlo codes in patient specific phantom calculations
Kamal Hadad1, Mahdi Saeedi-Moghadam2, Banafsheh Zeinali-Rafsanjani2,3
1Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Introduction:
Dose evaluation with two Monte Carlo codes using patient specific voxel phantom is presented in this paper. We employ both MCNPX and DOSXYZnrc to perform dosimetry for mathematical voxel phantoms generated by our in-house developed voxel phantom generator and EGSnrc/CTCreate respectively.
Material And Method:
Our case study was a 2.5 × 2.4 × 2.4 cm3 tumor in the middle lobe of right lung of a male patient exposed to 6MV parallel beam. In order to compare these Monte Carlo codes with together gross tumor volume (GTV) and organ at risks (OAR) doses and dose volume histograms (DVH) were calculated.
Results:
Comparing the mean absorbed dose results (in Gy) from both codes indicates that gross tumor volume, heart and spinal cord have 2% to 10% difference. The 10% difference between the codes were from the spinal cord region where was not in the therapy beam and it just received the scatter radiation. The dose volume DVH obtained from DOSXYZnrc results demonstrate a milder slope compared with MCNPX DVHs.
Conclusion:
It was revealed that MCNPX has some advantages in comparison to DOSXYZnrc, but it is important to consider that for equal precision in voxel dosimetry calculation, DOSXYZnrc runs faster than MCNPX and it is a great advantage.
More Related Videos
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...