Related Experiment Video
Updated: Mar 16, 2026

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
Published on: February 8, 2014
Lock-in camera based heterodyne holography for ultrasound-modulated optical tomography inside dynamic scattering
Yan Liu1, Yuecheng Shen1, Cheng Ma1
1Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis , St. Louis, Missouri 63130, USA.
Abstract:
Ultrasound-modulated optical tomography (UOT) images optical contrast deep inside scattering media. Heterodyne holography based UOT is a promising technique that uses a camera for parallel speckle detection. In previous works, the speed of data acquisition was limited by the low frame rates of conventional cameras. In addition, when the signal-to-background ratio was low, these cameras wasted most of their bits representing an informationless background, resulting in extremely low efficiencies in the use of bits. Here, using a lock-in camera, we increase the bit efficiency and reduce the data transfer load by digitizing only the signal after rejecting the background. Moreover, compared with the conventional four-frame based amplitude measurement method, our single-frame method is more immune to speckle decorrelation. Using lock-in camera based UOT with an integration time of 286 μs, we imaged an absorptive object buried inside a dynamic scattering medium exhibiting a speckle correlation time ([Formula: see text]) as short as 26 μs. Since our method can tolerate speckle decorrelation faster than that found in living biological tissue ([Formula: see text] ∼ 100-1000 μs), it is promising for in vivo deep tissue non-invasive imaging.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

