Orthodontic force production by closed coil springs
American Journal of Orthodontics
|October 1, 1978
Summary
This study found that orthodontic coil spring force depends on wire size, lumen size, and type. Current recommendations may generate excessive force, necessitating careful spring selection for effective tooth movement.
Area of Science:
- Biomaterials Science
- Orthodontics
- Mechanical Engineering
Background:
- Closed coil springs are crucial in orthodontics for applying controlled forces.
- Understanding factors influencing spring force is essential for predictable treatment outcomes.
Purpose of the Study:
- To investigate how wire size, lumen size, and wire type affect the force produced by closed coil springs.
- To determine if current orthodontic recommendations for coil springs generate optimal or excessive forces.
Main Methods:
- Systematic variation of wire size, lumen size, and wire material.
- Measurement of force output under controlled conditions for each variable.
Main Results:
- Increased wire size led to increased force output when lumen size was constant.
- Increased lumen size resulted in decreased force output when wire size was constant.
- Different wire types produced varying forces even with identical dimensions.
Conclusions:
- Orthodontic coil spring force is significantly influenced by physical dimensions and material properties.
- Current clinical recommendations may lead to the use of springs generating forces greater than necessary for optimal orthodontic tooth movement.
- Clinicians must exercise careful judgment in selecting appropriate closed coil springs based on specific clinical needs and desired force levels.