Continuous fraction collection of gas chromatographic separations with parallel mass spectrometric detection applied
Willem Jonker1, Nick Zwart2, Jan B Stöckl1
1Vrije Universiteit Amsterdam, Division of BioAnalytical Chemistry, De Boelelaan 1108, 1081 HZ Amsterdam, The Netherlands.
Abstract:
We describe the development and evaluation of a GC-MS fractionation platform that combines high-resolution fraction collection of full chromatograms with parallel MS detection. A y-split at the column divides the effluent towards the MS detector and towards an inverted y-piece where vaporized trap solvent is infused. The latter flow is directed outside the GC oven allowing subsequent condensation and stepwise collection of liquid fractions with trapped analytes on a 384-well plate. For study and optimization of the effluent split ratio, restriction capillaries of different lengths and diameters were evaluated. For a wide range of settings, local pressures were monitored during fractionation to assess the influence of MS vacuum and trap solvent infusion on the GC system stability. The platform performance was evaluated by GC-MS analysis and continuous fractionation of an n-alkane mixture followed by GC analysis of each fraction. Comparison of the on-line recorded and fraction-reconstructed chromatogram showed the GC separation is maintained during fractionation. Multiple fractionation cycles of the n-alkane sample on the same 384-well plate yielded a reconstructed chromatogram which was highly similar to that of a single analysis, demonstrating the high repeatability. The applicability of the GC-MS-fractionation platform for bioactivity screening was investigated by applying the AR-Ecoscreen reporter gene bioassay on fractions obtained after analysis of standard solutions and dust samples containing the anti-androgenic compounds vinclozolin and p,p'-DDE.
More Related Videos
07:55Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
Published on: June 21, 2019
08:06Absolute Quantification of Cell-Free Protein Synthesis Metabolism by Reversed-Phase Liquid Chromatography-Mass Spectrometry
Published on: October 25, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors