Related Experiment Video
Updated: Feb 27, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
IGRT and motion management during lung SBRT delivery
Vincent Caillet1, Jeremy T Booth1, Paul Keall2
1Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, Australia; School of Physics, University of Sydney, Sydney, Australia.
Patient motion during lung stereotactic body radiation therapy (SBRT) can lead to tumor misalignment and healthy tissue toxicity. Image-guided radiation therapy (IGRT) and motion management improve accuracy, enhancing patient care and quality of life.
Area of Science:
- Radiation Oncology
- Medical Physics
- Image-Guided Therapy
Background:
- Patient motion is a significant challenge in lung stereotactic body radiation therapy (SBRT), potentially causing tumor misalignment.
- Deviations from the planned radiation setup can result in underdosing the tumor or overdosing healthy lung tissue.
- These inaccuracies can lead to acute toxicities, negatively impacting patient quality of life and survival outcomes.
Purpose of the Study:
- To highlight the critical role of motion correction techniques in lung SBRT.
- To emphasize the benefits of image-guided radiation therapy (IGRT) and motion management devices.
- To demonstrate the feasibility of integrating advanced technologies for improved patient care.
Main Methods:
- Utilizing image-guided radiation therapy (IGRT) for precise tumor targeting.
- Implementing motion management devices to account for patient movement.
- Integrating these technologies with clinical linear accelerators.
Main Results:
- Correction for patient motion, whether pre-treatment or intra-treatment, is achievable.
- Image-guided techniques and motion management devices effectively address setup deviations.
- The integration of these technologies is feasible within clinical workflows.
Conclusions:
- Image-guided radiation therapy (IGRT) and motion management are crucial for accurate lung SBRT.
- These techniques mitigate risks associated with patient motion, improving treatment efficacy.
- Implementing advanced motion correction strategies enhances patient care standards and quality of life.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...