Intra-ocular lens optical changes resulting from the loading of dexamethasone
José M Artigas1,2, M Carmen García-Domene1,2, Amparo Navea1,3
1Fisabio Oftalmología Médica (FOM), Bifurcación Pío Baroja-General Avilés s/n, 46015 Valencia, Spain.
Biomedical Optics Express
|October 31, 2017
Summary
Loading hydrogel-silicone intraocular lenses (IOLs) with dexamethasone temporarily impairs optical quality, affecting modulation transfer function and spectral transmission. Optical properties largely recover after drug release.
Area of Science:
- Ophthalmology
- Materials Science
- Biomedical Engineering
Background:
- Intraocular lenses (IOLs) are crucial for vision restoration after cataract surgery.
- Drug-eluting IOLs offer potential for sustained intraocular drug delivery.
- Understanding the impact of drug loading on IOL optical performance is essential.
Purpose of the Study:
- To investigate the optical changes in hydrogel-silicone IOLs after loading with dexamethasone.
- To assess the reversibility of optical property changes post-drug release.
Main Methods:
- Prototype hydrogel-silicone IOLs were loaded with dexamethasone.
- Optical properties including modulation transfer function (MTF), spectral transmission, and diopter power were measured.
- Measurements were taken on drug-loaded, drug-released, and unloaded IOLs.
Main Results:
- Dexamethasone loading impaired the MTF and spectral transmission of hydrogel-silicone IOLs.
- Dioptric power remained unaffected by dexamethasone loading.
- Optical properties nearly recovered to baseline levels after the drug was released.
Conclusions:
- Loading hydrogel-silicone IOLs with dexamethasone causes temporary optical degradation.
- The observed optical changes are reversible upon drug release.
- These findings are important for the design of drug-eluting IOLs.
Related Concept Videos
Open Angle Glaucoma: Treatment
1.0K
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
1.0K
Angle Closure Glaucoma: Treatment
1.4K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.4K
Glaucoma: Overview
1.5K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.5K
Ophthalmic Drug Delivery Systems
54
Ophthalmic drug delivery faces major limitations due to poor absorption across the corneal membrane. This process is primarily driven by diffusion and is influenced by two main factors: the physicochemical properties of the drug and tear drainage. Most ophthalmic drugs, such as pilocarpine, epinephrine, atropine, and local anesthetics, are weak bases. They are typically formulated at an acidic pH to enhance chemical stability. However, this leads to high ionization, reducing their ability to...
54