Related Experiment Video
Updated: Feb 19, 2026

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
Skin temperature response to unilateral training measured with infrared thermography
Víctor L Escamilla-Galindo1, Alejandro Estal-Martínez1,2, Jakub G Adamczyk3
1Physical Activity Laboratory, Department of Sports, Faculty of Physical Activity and Sport Sciences, Technic University of Madrid, Madrid, Spain.
Abstract:
This study aimed to identify the skin temperature (Tsk) behavior to understand the acute cross-effect after unilateral training of lower-limbs. Seventeen healthy young men (weight, 75.2±5.5 kg; height, 1.8±0.1 m; age, 22.5±1.6 years) were divided into two groups: high-trained (n=8) and low-trained (n=9). All participants performed: (a) one-repetition maximum (1RM) testing protocol on the leg press, (b) a unilateral training protocol (4×10 repetitions at 70% of 1RM for leg press and 4×10 repetitions at 50% of 1RM for knee extension). Pre- and posttraining thermal images were recorded. The main results showed that independent of the limb (exercised vs. nonexercised), differences between low- and high-trained were observed for all regions of interest (ROI) except for the anterior knee: posttraining, 30-min and 60-min posttraining in nonexercised limb. The increase of contralateral Tsk was more than 50% on the ROIs corresponding to the exercises muscles 30-min post-training in low-trained but was not so high in high-trained (P<0.05). Low-trained subjects incremented more the Tsk than high-trained in both legs after exercise. In conclusion, we observed an acute contralateral Tsk effect to unilateral training on the Tsk of the nonexercised limb, reliant on the training level of the subject.
More Related Videos
08:16Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...