A Brun1, R Alcaraz Mor1,2, M Bourrelly3
1APHM, La Timone Hospital, Occupational Medicine and Health Department, F-13385 Marseille, France.
None:
The use of radiological activity in the operating room (OR) and a regulatory decrease of the eye lens dose warrant an assessment of how medical staff are protected from radiation. This study aims to evaluate practices and knowledge in radiation protection (RP) for OR doctors before and after training. A descriptive study of surgeons and anesthetists in a French public hospital center was conducted in 2016. An ad hoc questionnaire concerning occupational practices and knowledge about RP was distributed before and one month after RP training. Among 103 doctors attending the training, 90 answered the questionnaire before the training. Results showed a lack of knowledge and good practice in RP. Most of the participants (86.7%) had never been trained in RP and recognized insufficient knowledge. Most of them (92.2%) wore a lead apron, 50.0% a thyroid-shield, 5.6% lead glasses, 53.3% a passive dosimeter and 17.8% an electronic dosimeter. None of them benefitted from collective protective equipment such as a ceiling suspended screen. The questionnaire following the training was completed by only 35 doctors. A comparison before and after training results showed an improvement in knowledge (scores of correct responses: 5.5/16 before and 9.5/16 after training) but not in RP good practices (scores of correct responses: 3.2/7 before and 3.3/7 after training). One training session appears to be insufficient to improve the application of the safety rules when x-rays are used. Communication needs to be improved regarding RP among anesthetists and surgeons, such as training renewal, workstation analysis in OR related to x-ray use and occupational medical follow-up. Otherwise, radiological risks in OR need to be given better consideration, such as radio-induced cataract risk. It is necessary to encourage the use of dosimeters and protective equipment and to strengthen access to lead glasses and collective protective equipment, such as ceiling suspended screens. All these recommendations ensure the received dose is reduced to as low as is reasonably achievable.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Radiological Investigation I: X-ray and CT
Absorption of Radiation
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...