Comparison between endoscopic and external dacryocystorhinostomy by using the Lacrimal Symptom Questionnaire: A pilot

Wai Keat Wong1, Simon Dean2, Salil Nair1

  • 1From the Department of Otolaryngology, Head and Neck Surgery, Counties Manukau District Health Board, Auckland, New Zealand.

Summary

The endonasal approach to dacryocystorhinostomy (DCR) significantly improves quality of life more than the external approach for nasolacrimal duct obstruction. Both methods offer benefits, but endonasal DCR shows superior outcomes in patient-reported symptom relief.

Related Concept Videos

Endoscopic Studies II: Thoracocentesis01:26

Endoscopic Studies II: Thoracocentesis

Thoracentesis(Thoracocentesis), commonly known as pleural tap, is a medical procedure where a 22 gauge needle is inserted into the pleural space, the area between the lung and chest wall. This procedure is commonly performed to diagnose or treat various respiratory disorders.
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
1.5K
Endoscopic Studies I: Bronchoscopy and Thoracoscopy01:30

Endoscopic Studies I: Bronchoscopy and Thoracoscopy

Endoscopy is a non-surgical medical technique used to examine a person's internal organs and vessels. This lesson will focus on two types of endoscopic studies: bronchoscopy and thoracoscopy.
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
682
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
496
The Sense of Self: Reflected Self-Appraisal and Social Comparison02:57

The Sense of Self: Reflected Self-Appraisal and Social Comparison

According to Charles Cooley, we base our image on what we think other people see (Cooley 1902). We imagine how we must appear to others, then react to this speculation. We don certain clothes, prepare our hair in a particular manner, wear makeup, use cologne, and the like—all with the notion that our presentation of ourselves is going to affect how others perceive us. We expect a certain reaction, and, if lucky, we get the one we desire and feel good about it. But more than that, Cooley...
56.2K
Work Done on a System by External Force01:11

Work Done on a System by External Force

The work done by an external force on a particle changes its kinetic energy. However, internal forces must also be considered for a system of interacting particles. The potential energy formulation helps formulate the effect of internal forces. The net work done by an external force can be written in terms of the total change of mechanical energy, which includes both kinetic and potential energies.
In the presence of a non-conservative opposing force, like friction, some part of the work done...
3.0K
Diabetes: Symptoms, Diagnosis, and Complications01:15

Diabetes: Symptoms, Diagnosis, and Complications

For most patients, experiencing several weeks of polyuria, polydipsia, fatigue, and significant weight loss may indicate the presence of diabetes. Furthermore, adults displaying the phenotypic appearance of type 2 diabetes (particularly those who are obese and not initially insulin-requiring), may have islet cell autoantibodies, suggesting autoimmune-mediated β cell destruction and a diagnosis of latent autoimmune diabetes of adults (LADA). The categorization of glucose homeostasis is...
2.4K