Pressure Pulse Distortion by Needle and Fiber-Optic Hydrophones due to Nonuniform Sensitivity
None:
Needle and fiber-optic hydrophones have frequency-dependent sensitivity, which can result in substantial distortion of nonlinear or broadband pressure pulses. A rigid cylinder model for needle and fiber-optic hydrophones was used to predict this distortion. The model was compared with measurements of complex sensitivity for a fiber-optic hydrophone and three needle hydrophones with sensitive element sizes ( ) of 100, 200, 400, and . Theoretical and experimental sensitivities agreed to within 12 ± 3% [root-mean-square (RMS) normalized magnitude ratio] and 8° ± 3° (RMS phase difference) for the four hydrophones over the range from 1 to 10 MHz. The model predicts that distortions in peak positive pressure can exceed 20% when and spectral index (SI) >7% and can exceed 40% when and SI >14%, where is the wavelength of the fundamental component and SI is the fraction of power spectral density contained in harmonics. The model predicts that distortions in peak negative pressure can exceed 15% when . Measurements of pulse distortion using a 2.25 MHz source and needle hydrophones with , 400, and agreed with the model to within a few percent on the average for SI values up to 14%. This paper 1) identifies conditions for which needle and fiber-optic hydrophones produce substantial distortions in acoustic pressure pulse measurements and 2) offers a practical deconvolution method to suppress these distortions.
Related Concept Videos
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...