Publisher Correction: Intercalation events visualized in single microcrystals of graphite

Edward R White1, Jared J Lodico2, B C Regan3

  • 1Department of Physics & Astronomy and California NanoSystems Institute, University of California, Los Angeles, CA, 90095, USA. ewhite@physics.ucla.edu.

Nature Communications
|February 21, 2018
PubMed
Summary

The Peer Review File was updated to remove confidential editor comments after publication. This ensures transparency and integrity in the scientific publishing process.

Related Concept Videos

Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
302
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
559
Integration of Synaptic Events01:28

Integration of Synaptic Events

Synaptic integration mainly includes the summation of graded potentials. Graded potentials, regardless of their type, cause subtle alterations in membrane voltage, resulting in either depolarization or hyperpolarization. These incremental changes, when combined or summed, can propel the neuron toward its threshold. Consider, for example, a membrane experiencing a +15 mV shift, causing it to depolarize from -70 mV to -55 mV. In this scenario, graded potentials govern the membrane's ability to...
4.2K
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Schwarzschild Radius and Event Horizon01:21

Schwarzschild Radius and Event Horizon

No object with a finite mass can travel faster than the speed of light in a vacuum. This fact has an interesting consequence in the domain of extremely high gravitational fields.
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...
2.8K
Visual System01:26

Visual System

Light enters the eye through the cornea, a transparent, dome-shaped surface covering the surface of the eyeball that helps to direct and focus incoming light. This light is then channeled toward the pupil, an adjustable opening whose size is controlled by the iris. The iris, a pigmented muscle, regulates the amount of light entering the eye by contracting or dilating the pupil, thereby ensuring optimal light levels for clear vision.
Once through the pupil, the light passes through the lens, a...
1.9K