Analysis of β-Amyloid-induced Abnormalities on Fibrin Clot Structure by Spectroscopy and Scanning Electron Microscopy
Published on: November 30, 2018
Comparative Study on the Cutting Effectiveness and Heat Generation of Rotary Instruments Versus Piezoelectric Surgery
Purpose:
The search for optimizing rehabilitation results with the use of osseointegrated implants has led oral surgeons to look for other technologies that can provide better predictability for treatments; however, effectiveness must be considered as well. This study aimed to compare temperature variation during preparation of implant surgical beds using conventional rotary implant burs versus ultrasonic tips and to study perforation effectiveness by analyzing the functional wear of both systems and the influence of such wear on the overheating of cortical bone.
Materials And Methods:
This evaluation was made using thermocouples placed in fresh bovine cortical bone (femur) and connected to a data collector so that the recorded temperatures could provide the thermal behavior of both systems after repeated use of the burs and piezoelectric tips, to compare the wear and the loss of cutting efficiency. Scanning electron microscopy (SEM) was used to compare the topography of both systems' perforations. Biostatistics assays were performed comparing both techniques as well.
Results:
The collected data and images showed that the wear of the burs and tips did not significantly influence the temperature variation, and the greatest variation occurred in the piezoelectric system for preparations of 13-mm depth. The SEM images show a different surface topography between both systems. While the burs cut the bone, showing a smooth surface, the piezoelectric tips condense the bone and present a rough surface.
Conclusion:
The use of either rotatory burs or piezoelectric tips generates a temperature that does not affect the tissue healing. Burs create a smooth surface, and piezoelectric tips show a more rough and condensed bone surface. The wear of both systems does not have a relevant increase in temperature after the preparation of 30 surgical beds.
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Electronic Distance Measuring Instruments
Comparing the Survival Analysis of Two or More Groups
Quantifying Heat
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Overview of Electron Microscopy