Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
Perceptual Image Quality Metrics Concept in Continuous Scanning 2D Laser Ablation-Inductively Coupled Plasma Mass
Johannes T van Elteren1, Martin Šala1, Vid S Šelih1
1Department of Analytical Chemistry , National Institute of Chemistry , Hajdrihova 19 , 1000 Ljubljana , Slovenia.
Abstract:
This work focuses on the structural similarity (SSIM) index as a tool for optimization of the perceived visual image quality obtainable by continuous scanning 2D LA-ICPMS bioimaging, but also other mass spec imaging techniques may benefit from this approach. This index quantifies the differences between a distorted image and a reference image based on parameters associated with luminance, contrast, and noise. Since reference images are not normally available, a protocol was developed to virtually apply distortion-related information introduced by the LA-ICPMS imaging system to a reference image of one's choice. Distortion-related information in the form of blur and noise was experimentally retrieved from line scans across a laser milled knife edge on custom-prepared gelatin standards (mimicking proteinaceous biomatrixes). Distorted images were generated via computational procedures developed earlier, warranting objective image quality assessment via the SSIM indices. We illustrate the potential of this approach for image quality optimization for a suite of LA-ICPMS imaging conditions.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Formula Mass and Mole Concepts of Compounds
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Mass Spectrometry: Overview