Related Experiment Video
Updated: Feb 10, 2026

Ultrasound Tissue Characterization of Human Achilles Tendon by Stability Quantification of Echo Patterns
Published on: September 5, 2025
Intravoxel incoherent motion (IVIM) imaging in human achilles tendon
Kenneth Wengler1, Takeshi Fukuda2, Dharmesh Tank2
1Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA.
Background:
Limited microcirculation has been implicated in Achilles tendinopathy and may affect healing and disease progression. Existing invasive and noninvasive approaches to evaluate tendon microcirculation lack sensitivity and spatial coverage.
Purpose:
To develop a novel Achilles tendon intravoxel incoherent motion (IVIM) MRI protocol to overcome the limitations from low tendon T2 /T2 * value and low intratendinous blood volume and blood velocity to evaluate tendon microcirculation.
Study Type:
Prospective.
Subjects:
Sixteen healthy male participants (age 31.0 ± 2.1) were recruited.
Field Strength/Sequence:
A stimulated echo readout-segmented echo planar imaging (ste-RS-EPI) IVIM sequence at 3.0T.
Assessment:
The feasibility of the proposed ste-RS-EPI IVIM protocol combined with Achilles tendon magic angle effect was evaluated. The sensitivity of the protocol was assessed by an exercise-induced intratendinous hemodynamic response in healthy participants. The vascular origin of the observed IVIM signal was validated by varying the diffusion mixing time and echo time.
Statistical Tests:
Two-tailed t-tests were used to evaluate differences (P < 0.05 was considered significant).
Results:
Consistent with known tendon hypovascularity, the midportion Achilles tendon at baseline showed significantly lower IVIM-derived perfusion fraction (fp ) (3.1 ± 0.9%) compared to the proximal and distal Achilles tendon (6.0 ± 1.8% and 6.1 ± 2.0%, respectively; P < 0.01). Similarly, the midportion Achilles tendon exhibited significantly lower baseline blood flow index (D*×fp ) (40.9 ± 19.2, 18.3 ± 5.3, and 32.0 ± 9.4 in proximal, midportion, and distal Achilles tendon, respectively; P < 0.01). Eccentric heel-raise exercise led to ∼2 times increase of Achilles tendon blood flow in healthy participants. Consistent with its vascular origin, the estimated fp demonstrated a high dependency to IVIM protocol parameters, while the T1 /T2 -corrected absolute intratendinous microvascular blood volume fraction (Vb ) did not vary.
Data Conclusion:
Achilles tendon ste-RS-EPI IVIM noninvasively assessed baseline values and exercise-induced changes to tendon microcirculation in healthy tendon.
Level Of Evidence:
1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:1690-1699.
More Related Videos
08:19Author Spotlight: Unraveling the Mechanobiology of Tendon Impingement – A Multiaxial Murine Hind Limb Explant Model
Published on: December 8, 2023
07:51Effects of Allogeneic Platelet-Rich Plasma PRP on the Healing Process of Sectioned Achilles Tendons of Rats: A Methodological Description
Published on: March 19, 2018
Related Concept Videos
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Equation of Motion: General Plane motion - Problem Solving
The friction between the roller and the ground is characterized by two coefficients. The static friction coefficient is 0.15, while the kinetic friction coefficient is 0.1. These values are crucial in understanding the interaction between...
Projectile Motion: Example
When we speak of the range (R) of a projectile on...
Simple Harmonic Motion and Uniform Circular Motion
There is an easy way to produce simple harmonic motion by using uniform circular motion. For instance, consider a ball attached to a uniformly rotating...
Torque Free Motion