Condensin I protects meiotic cohesin from WAPL-1 mediated removal

Margarita R Hernandez1, Michael B Davis1, Jianhao Jiang1

  • 1Department of Molecular, Cellular, and Developmental Biology, University of Michigan, Ann Arbor, MI, United States of America.

Plos Genetics
|May 17, 2018
PubMed

Related Concept Videos

Condensins02:15

Condensins

Condensins are large protein complexes that use ATP to fuel the assembly of chromosomes during mitosis. They transform the tangled, shapeless mass of post-interphase DNA into individualized chromosomes by compacting, organizing, and segregating chromosomal DNA.
The plant and animal cells contain two types of condensin complexes—condensin I and condensin II. Both complexes have five subunits: two SMC (Structural Maintenance of Chromosomes) subunits, a kleisin subunit, and two HEAT-repeat...
4.7K
Cohesins02:20

Cohesins

Cohesin protein complexes are a molecular glue that holds two sister chromatids together. They play an important role both in mitosis and meiosis. In mitosis, all cohesin complexes present on the chromosomes are removed before the start of the anaphase stage.
Cohesin complexes in Meiotic Division
Meiosis involves two distinct rounds of chromosomal segregation and cell divisions— Meiosis I followed by Meiosis II – producing four daughter cells. Meiosis I includes the separation of...
5.7K
Protection of Alcohols02:31

Protection of Alcohols

This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.1K
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
812
Protecting Self-Esteem01:27

Protecting Self-Esteem

Self-esteem, a central component of psychological well-being, is actively maintained through various cognitive and behavioral strategies. Individuals employ specific mechanisms to preserve a positive self-concept and mitigate threats to their self-worth, particularly in contexts involving social evaluation or personal feedback. Four primary techniques are commonly used to sustain self-esteem.Manipulating AppraisalsOne prominent strategy involves manipulating appraisals from others. Individuals...
234
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
447