Related Experiment Video
Updated: Feb 9, 2026

Nuclei Isolation from Whole Tissue using a Detergent and Enzyme-Free Method
Published on: June 24, 2020
Know your detergents: A case study on detergent background in negative stain electron microscopy.
Theresa Gewering1, Dovile Januliene1, Anne B Ries1
1Department of Structural Biology, Max Planck Institute of Biophysics, Max-von-Laue Strasse 3, 60438 Frankfurt/Main, Germany.
Negative stain electron microscopy (EM) is a fast, inexpensive tool for evaluating samples before high-resolution cryo-EM or X-ray crystallography. However, detergent micelles can create background artifacts, leading to misinterpretation of sample quality.
Area of Science:
- Structural biology
- Biophysical techniques
- Macromolecular complex analysis
Background:
- Electron cryo-microscopy (cryo-EM) provides near-atomic resolution 3D structures but requires highly optimized samples.
- Negative stain EM is a rapid, cost-effective preliminary method for sample quality control, crucial for cryo-EM and X-ray crystallography.
- Interpreting negative stain EM data requires careful consideration of potential artifacts, such as background from detergent micelles.
Purpose of the Study:
- To investigate and highlight the common artifact of background signal from detergent micelles in negative stain EM.
- To demonstrate how detergent micelles can be misinterpreted as protein samples, affecting sample quality assessment.
- To provide a template for evaluating negative stain EM images, particularly for small membrane proteins.
Main Methods:
- Case study analysis of commonly used detergents in negative stain EM.
- Microscopy evaluation of detergent behavior and background signal generation.
- Comparison of background signal across different detergents and concentrations relative to critical micelle concentration (CMC).
Main Results:
- Most detergents produce significant background signal in negative stain EM, even at concentrations below their nominal CMC.
- This background signal can be easily confused with actual detergent-embedded protein samples.
- Unawareness of this artifact can lead to incorrect assessments of sample quality and homogeneity.
Conclusions:
- Detergent-induced background is a prevalent issue in negative stain EM that can compromise data interpretation.
- Careful evaluation of negative stain EM images is essential to avoid misinterpreting detergent artifacts as protein signals.
- This study serves as a guide for researchers to identify and mitigate background artifacts in their EM sample quality control processes.
Related Concept Videos
Detergent Purification of Membrane Proteins
Overview of Electron Microscopy
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Transmission Electron Microscopy
Immunogold Electron Microscopy
Cryo-electron Microscopy

