Related Experiment Video
Updated: Feb 9, 2026

A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
Published on: September 16, 2017
Estimating Lengths of Semitendinosus and Gracilis Tendons by Magnetic Resonance Imaging
Omer A Ilahi1, R Scott Staewen2, Eugene F Stautberg3
1Texas Arthroscopy and Sports Medicine Institute, Houston, Texas, U.S.A..
Purpose:
To determine whether preoperative magnetic resonance imaging (MRI) can help predict the tendon-only length of the semitendinosus (ST) and the gracilis (G).
Methods:
The distance from the tibial insertion to the distal-most aspect of the musculotendinous junction (MTJ) of the ST and G was estimated on preoperative MRI scans of patients undergoing primary anterior cruciate ligament (ACL) reconstruction with single-bundle, quadruple-stranded hamstring autograft. This MRI tendon-only length, measured by a musculoskeletal radiologist blinded to surgical findings, was compared to the actual tendon-only length measured upon harvesting each tendon.
Results:
Among the 42 patients comprising the study population, there was very strong correlation between the estimates of tendon-only length made by MRI and surgical measurements for both the ST (Spearman coefficient = 0.83; P < .0001) and the G (Spearman coefficient = 0.82; P < .0001). The difference between MRI and surgical measurements did not exceed 3 cm for any of the 84 harvested hamstring tendons. Bland-Altman plots confirmed agreement between the 2 measurement methods. There was also strong correlation between the surgically measured tendon-only length of the ST and its G counterpart (Spearman coefficient = 0.68; P < .0001).
Conclusions:
MRI estimates of tendon-only length for both the ST and G very strongly correlate with operative measurements of these lengths; the discrepancy between these 2 measurement methods was found to not exceed 3 cm when the MTJ of these tendons is visible on MRI scans.
Level Of Evidence:
Level III, comparative study.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Resonance
Atomic Nuclei: Magnetic Resonance
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Bond Energies and Bond Lengths

