Utilization of Open Source Technology to Create Cost-Effective Microscope Camera Systems for Teaching

Anil Reddy Konduru1, Balasaheb R Yelikar1, K V Sathyashree1

  • 1Department of Pathology, Shri B. M. Patil Medical College Hospital and Research Center, BLDE (Deemed to be University), Vijayapura, Karnataka, India.

Summary

Low-cost, portable microscopy camera systems were developed using open-source technology. This innovation makes advanced digital microscopy accessible for education and research, overcoming the limitations of expensive OEM equipment.

Related Concept Videos

Comparative Excretory Systems02:24

Comparative Excretory Systems

Animals have evolved different strategies for excretion, the removal of waste from the body. Most waste must be dissolved in water to be excreted, so an animal’s excretory strategy directly affects its water balance.
26.7K
Hybridoma Technology01:31

Hybridoma Technology

Hybridoma technology is used for the large-scale production of monoclonal antibodies. Monoclonal antibodies bind to only a single antigenic determinant or epitope. Such antibodies are used in research, diagnostics, and disease therapy. The hybridoma technology established in 1975 by Georges Köhler and Cesar Milstein was awarded the Nobel Prize in Medicine in 1984 for revolutionizing research and therapy.
Hybridoma Selection
Commonly used fusion techniques — electroporation,...
17.7K
Second Order systems II01:18

Second Order systems II

In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
412
First Order Systems01:21

First Order Systems

First-order systems, such as RC circuits, are foundational in understanding dynamic systems due to their straightforward input-output relationship. Analyzing their responses to different input functions under zero initial conditions reveals significant insights into system behavior.
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
433
Second Order systems I01:20

Second Order systems I

A servo system exemplifies a second-order system, featuring a proportional controller and load elements that ensure the output position aligns with the input position. The relationship between these components is described by a second-order differential equation. Applying the Laplace transform under zero initial conditions yields the transfer function, showing how inputs are converted to outputs in the system.
By reinterpreting the system, one can derive the closed-loop transfer function, which...
603
Sinusoidal Sources01:18

Sinusoidal Sources

Direct current (DC) refers to an electric current that flows in a single direction, maintaining a constant polarity. This is in contrast to alternating current (AC), which periodically changes its direction and magnitude. AC forms the backbone of modern electricity transmission and distribution systems due to its efficient long-distance transmission capabilities.
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
1.2K