Multi-Point Wireless Temperature Sensing System for Monitoring Pharmaceutical Lyophilization
Xiaofan Jiang1, Tong Zhu2, Tatsuhiro Kodama3
1School of Electrical and Computer Engineering-Birck Nanotechnology Center, Purdue University, West Lafayette, IN, United States.
Abstract:
This work presents the design and evaluation of a fully wireless, multi-point temperature sensor system as a Process Analytical Technology (PAT) for lyophilization. Each sensor contains seven sensing elements which measure the product temperature at various positions of the contents of a glass vial. The sensor performance was studied by freeze drying experiments with sensor placement in both center and edge of full shelf of 6R glass vials with 4 ml fill volume. Product temperature profile and primary drying time measured at the bottom center position in the glass vial by the wireless sensor as well as the primary drying time are in close comparison with the thermocouple data. The drying times during primary drying were determined at the top, higher middle, lower middle and bottom positions which are 3.26 mm apart vertically in the vial by the wireless sensor based on the temperature profile measured at different positions. For a center vial, the drying time from the start of primary drying to each layer was measured at 3.9, 9.3, 14.2, and 21 h respectively, allowing to track the sublimation interface during primary drying phase. In addition, sublimation rate at each layer was calculated based on the drying time and theoretical weight loss of ice in the product. The sublimation rate at the beginning of the primary drying was similar to the sublimation rate by gravimetric method. Furthermore, the vial heat transfer coefficient (K ) was also calculated based on the sublimation rate. Thus, allowing the use of the multi-point wireless sensor to rapidly monitor the sublimation rate and K for every batch as continuous process verification. Similar tests were also conducted with 3% w/v mannitol solutions and the results were consistent demonstrating potential for real-time monitoring, process verification and cycle optimization for pharmaceutical lyophilization.
More Related Videos
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
07:25Simultaneous Monitoring of Wireless Electrophysiology and Memory Behavioral Test as a Tool to Study Hippocampal Neurogenesis
Published on: August 20, 2020
Related Concept Videos
Pharmaceutical Equivalents
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Introduction to Special Senses
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Tactile and Chemical Senses
Pharmaceutical Alternatives: Excipients and Impurities-Related Therapeutic Nonequivalence