Related Experiment Video
Updated: Feb 5, 2026

Microfluidic Pneumatic Cages: A Novel Approach for In-chip Crystal Trapping, Manipulation and Controlled Chemical Treatment
Published on: July 12, 2016
Advanced fabrication approaches to controlled delivery systems for epilepsy treatment
Gilles Sebastiaan van Tienderen1,2, Marius Berthel1,3, Zhilian Yue1
1a ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, AIIM Facility , University of Wollongong , Wollongong , Australia.
Introduction:
Epilepsy is a chronic brain disease characterized by unprovoked seizures, which can have severe consequences including loss of awareness and death. Currently, 30% of epileptic patients do not receive adequate seizure alleviation from oral routes of medication. Over the last decade, local drug delivery to the focal area of the brain where the seizure originates has emerged as a potential alternative and may be achieved through the fabrication of drug-loaded polymeric implants for controlled on-site delivery.
Areas Covered:
This review presents an overview of the latest advanced fabrication techniques for controlled drug delivery systems for refractory epilepsy treatment. Recent advances in the different techniques are highlighted and the limitations of the respective techniques are discussed.
Expert Opinion:
Advances in biofabrication technologies are expected to enable a new paradigm of local drug delivery systems through offering high versatility in controlling drug release profiles, personalized customization and multi-drug incorporation. Tackling some of the current issues with advanced fabrication methods, including adhering to GMP-standards and industrial scale-up, together with innovative solutions for complex designs will see to the maturation of these techniques and result in increased clinical research into implant-based epilepsy treatment.
Abbreviations:
GMP: Good manufacturing process; DDS(s): Drug delivery system(s); 3D: Three-dimensional; AEDs: Anti-epileptic drugs; BBB: Blood brain barrier; PLA: Polylactic acid; PLGA: Poly(lactic-co-glycolic acid); PCL: poly(ɛ-caprolactone); ESE: Emulsification solvent evaporation; O/W: Oil-in-water; W/O/W: Water-in-oil-in-water; DZP: Diazepam; PHT: Phenytoin; PHBV: Poly(hydroxybutyrate-hydroxyvalerate); PEG: Polyethylene glycol; SWD: Spike-and-wave discharges; CAD: Computer aided design; FDM: Fused deposition modeling; ABS: Acrylonitrile butadiene styren; eEVA: Ethylene-vinyl acetate; GelMA: Gelatin methacrylate; PVA: Poly-vinyl alcohol; PDMS: Polydimethylsiloxane; SLA: Stereolithography; SLS: Selective laser sintering.
Related Concept Videos
Control Systems
At the heart...
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Transfer Function in Control Systems
To derive the transfer function, consider a general nth-order linear time-invariant...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...

