Biomechanical Comparison of Intramedullary Beaming and Plantar Plating Methods for Stabilizing the Medial Column of
Melissa M Simonik1, Jessica Wilczek2, Guido LaPorta2
1Doctoral Candidate, Department of Mechanical Engineering, Binghamton University, Binghamton, NY.
Abstract:
Charcot neuroarthropathy often results in a rocker-bottom foot deformity, which leads to ulceration, infection, and amputation. Surgical techniques to reconstruct the medial column include intramedullary beaming and plantar plating, with disagreement regarding which approach provides a stronger construct with superior stability and fixation. The objective of the present cadaveric study was to compare the construct rigidity and strength of beaming and plantar plating of the medial column of 5 paired bilateral feet. Cannulated titanium beams and plates were implanted in the right and left feet, respectively. The specimens underwent interval testing to generate load-displacement and load-strain curves, cyclic loading at low loads, and then were loaded to failure. The beamed and plated specimens had statistically similar stiffness (p = .80) with a mean of 11.1 ± 3.9 N/mm and 11.3 ± 5.9 N/mm, respectively. The beamed and plated specimens had a statistically similar mean strain of -164 ± 75.1 µε and -208 ± 87.8 µε on the dorsal (p = .45) and 92 ± 90.4 µε and 221 ± 100.5 µε on the plantar (p = .08) surfaces of the first metatarsal. Three beamed specimens failed from talus fracture (60%), and 2 beams plastically deformed (40%). Two plated specimens failed from talus fracture (40%), and 3 experienced screw pullout (60%). The beamed and plated specimens withstood a mean load to failure of 234 ± 111.4 N and 140 ± 68.9 N, respectively, with the difference statistically significant (p = .04). Overall, beaming was more robust than plantar plating, because it was less sensitive to specimen size and bone quality.
Related Concept Videos
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Muscles of the Leg that Move the Foot and Toes
Anterior Compartment
The anterior compartment includes muscles that contribute to the dorsiflexion of the foot. This compartment houses the tibialis anterior, extensor hallucis longus, and extensor digitorum longus muscles....
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...