Point Defects and Green Emission in Zero-Dimensional Perovskites

Jun Yin1, Haoze Yang1, Kepeng Song2

  • 1Division of Physical Science and Engineering , King Abdullah University of Science and Technology , Thuwal 23955-6900 , Kingdom of Saudi Arabia.

Summary

Bromide vacancies in zero-dimensional (0D) perovskites are identified as the source of green light emission. This defect-induced luminescence in Cs4PbBr6 nanocrystals enhances their potential for optoelectronic applications.

Related Concept Videos

Emission Spectra02:39

Emission Spectra

When solids, liquids, or condensed gases are heated sufficiently, they radiate some of the excess energy as light. Photons produced in this manner have a range of energies, and thereby produce a continuous spectrum in which an unbroken series of wavelengths is present.
76.4K
Green Algae01:21

Green Algae

Green algae, also referred to as chlorophytes, are different from red algae in having the chloroplasts containing chlorophylls a and b, which give them their distinct green hue. However, they lack phycobiliproteins, preventing them from developing the red or blue-green pigmentation seen in red algae. In terms of photosynthetic pigment composition, green algae closely resemble plants and share a close evolutionary relationship with them. Taxonomically Green algae belong to Phylum Chlorophyta in...
849
Lumber Defects01:23

Lumber Defects

Lumber defects, which can affect both the appearance and structural integrity of wood, include a variety of growth and manufacturing flaws. Growth defects such as knots and knotholes occur where branches were once attached to the tree trunk, with knotholes forming when these knots fall out. Other natural defects include decay and insect damage, which compromise the wood's strength and durability.
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
527
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.5K
Dimensional Analysis03:40

Dimensional Analysis

Dimensional analysis, also known as the factor label method, is a versatile approach for mathematical operations. The main principle behind this approach is: the units of quantities must be subjected to the same mathematical operations as their associated numbers. This method can be applied to computations ranging from simple unit conversions to more complex and multi-step calculations involving several different quantities and their units.
Conversion Factors and Dimensional Analysis
The unit...
64.8K
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
643