Indirect Measurement of CRAC Channel Activity Using NFAT Nuclear Translocation by Flow Cytometry in Jurkat Cells

María D Carretta1, María A Hidalgo1, Rafael A Burgos2

  • 1Faculty of Veterinary Science, Laboratory of Molecular Pharmacology, Institute of Pharmacology, Universidad Austral de Chile, Valdivia, Chile.

Related Concept Videos

Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
16.3K
Uniform Depth Channel Flow01:27

Uniform Depth Channel Flow

Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...
589
Energy Considerations in Open Channel Flow01:27

Energy Considerations in Open Channel Flow

Open channel flow, where a fluid flows with a free surface exposed to the atmosphere, is primarily governed by gravitational and surface effects, distinguishing it from closed conduit or pipe flow. In open channels such as rivers, canals, and artificial channels, energy analysis provides valuable insights into flow behavior and the relationship between depth, velocity, and slope.Specific Energy and Flow DepthIn open channel flow, the specific energy, E, combines the gravitational potential...
609
Microbial Growth Measurement: Indirect Methods01:27

Microbial Growth Measurement: Indirect Methods

Estimating microbial growth is essential for understanding population dynamics and environmental adaptations. Indirect methods provide valuable insights by measuring parameters such as turbidity, metabolic activity, and biomass, enabling efficient and reproducible assessments.During exponential growth, microbial cells scatter light proportionally to their biomass, a principle used in turbidity measurements. About one million cells per milliliter produce detectable scattering, which a...
1.5K
Uniform Depth Channel Flow: Problem Solving01:18

Uniform Depth Channel Flow: Problem Solving

To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by...
514
Nuclear Export of mRNA02:31

Nuclear Export of mRNA

Before mRNAs are exported to the cytoplasm, it is crucial to check each mRNA for structural and functional integrity. Eukaryotic cells use several different mechanisms, collectively known as mRNA surveillance, to look for irregularities in mRNAs. Irregular or aberrant mRNA are rapidly degraded by various enzymes. If a defective mRNA escapes the surveillance, it would be translated into a protein which would either be non-functional or not function properly. One of the primary irregularities in...
8.8K