Related Experiment Video
Updated: Feb 5, 2026

Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
Prevalence and Doppler Echocardiographic Characteristics of Normally Functioning Mitral Prostheses with Mean Gradient
Chad M House1,2, Katie A Moriarty1,3,4, William B Nelson1,3,4
1Regions Hospital Heart Center, St. Paul, MN, USA.
Background:
The study aim was to determine the prevalence of normally functioning mitral prostheses with mean gradient ≥10 mmHg, and to identify the characteristics and echocardiographic variables that might be useful to distinguish normal function from dysfunction.
Methods:
A total of 56 consecutive patients with a prosthetic mitral valve and mean gradient ≥10 mmHg was retrospectively identified. Nineteen patients without subsequent imaging confirming normal prosthesis function or dysfunction were excluded; hence, 37 patients were classified as obstruction, insufficiency, or normal prosthesis (high-gradient; NPHG). A comparison group of 25 patients with a mean transprosthetic gradient of ≤5 mmHg (low-gradient group) was also identified.
Results:
Of the 37 patients, seven (19%) had obstruction, 10 (27%) had significant valvular or perivalvular insufficiency, and 20 (54%) were deemed NPHG. NPHG patients had a similar net atrioventricular compliance (Cn) to those with obstruction and insufficiency, which was significantly lower than the low-gradient group. The cardiac index (CI) was significantly higher in the NPHG group (3.4 ± 0.9 l/min/m2) compared to all other groups (p = 0.001). Receiver operator characteristic curves showed that the indexed effective orifice area (EOAi), effective orifice area (EOA) and velocity-time integral ratio distinguished NPHG from abnormal prosthesis function in patients with mean gradients ≥10 mmHg (area under curve = 0.92, 0.86, and 0.82, respectively).
Conclusions:
The study data suggested that a plurality of individuals with a mean transprosthetic mitral gradient ≥10 mmHg will be found to have a normally functioning prosthesis. Most of these patients will have a small EOAi, a reduced Cn, and a relatively increased CI.
More Related Videos
09:05Assessment of Cardiac Morphological and Functional Changes in Mouse Model of Transverse Aortic Constriction by Echocardiographic Imaging
Published on: June 21, 2016
07:55Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice
Published on: April 7, 2022
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Characteristics and Functions of Blood
The primary function of blood is to transport oxygen and carbon dioxide between tissues and the lungs. Oxygenated blood is bright red, while oxygen-depleted blood is darker. It also carries...
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Doppler Effect - I
Doppler Effect - II
Characteristics of Life