Related Experiment Video
Updated: Feb 4, 2026

fMRI Validation of fNIRS Measurements During a Naturalistic Task
Published on: June 15, 2015
Continued Validation of Ultrasound Guidance Targeting Tasks: Assessment of Internal Structure
J F Nitsche1, S Conrad1, S Hoopes1
1Division of Maternal Fetal Medicine, Department of OB-GYN, Wake Forest School of Medicine, Winston-Salem, NC 27157.
Rationale And Objectives:
We previously demonstrated validity evidence for our novel ultrasound-guided invasive procedure targeting tasks in the content, response process, relations with other variables, and consequences validity domains. Here, we investigate their internal structure by assessing their interrater, intrarater, and test-retest reliability.
Methods:
In this Institutional Review Board approved nonrandomized interventional trial first year medical students performed our previously described dowel and straw ultrasound guidance targeting tasks as a pretest. Afterward, the training group had four weekly 1-hour training sessions. The control group had no further training. Both groups then had a posttest for both tasks. The training group was re-evaluated 2 and 5 months later. Completion time in seconds, errors, and error adjusted time (5 seconds penalty/error) were recorded. Pretest and posttest performance was compared within groups, and the amount of improvement from pretest to posttest was compared between groups. Interrater, intrarater, and test-retest interclass correlation coefficients (ICC) were calculated.
Results:
Although some improvements from pretest to posttest were seen in both groups, greater improvements were seen in the training group. This skill was retained for at least several months. The interrater and intrarater ICCs were excellent (range 0.83-0.93). The test-retest ICCs were good to excellent in all but one performance measure (0.50-0.78).
Conclusion:
Student performance on the targeting tasks improved markedly after training and persisted for several months. The interrater and intrarater reliability were excellent, while the test-retest reliability was good. This provides additional validity evidence for our novel ultrasound-guided invasive procedure targeting curriculum.
More Related Videos
08:37Focused Ultrasound Induced Blood-Brain Barrier Opening for Targeting Brain Structures and Evaluating Chemogenetic Neuromodulation
Published on: December 22, 2020
10:21Author Spotlight: Streamlining Protein Target Prediction and Validation via Molecular Docking and CETSA
Published on: February 23, 2024
Related Concept Videos
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Internal Receptors
Reliability and Validity
Internal Energy
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Data Validation
Key parameters for method validation include: