Related Experiment Video
Updated: Feb 3, 2026

Transvaginal Mesh Insertion in the Ovine Model
Published on: July 27, 2017
[Initial Experience of Stereotactic EEG Insertion with Anchor Bolt:Problem Extraction and Improvement of Insertion
Taku Inada1, Takayuki Kikuchi, Katsuya Kobayashi
1Department of Neurosurgery, Kyoto University Graduate School of Medicine.
Abstract:
In recent years, stereotactic electroencephalography(SEEG)has been focused on as a new invasive method for epileptic focus detection. Although the covering area of the brain surface is smaller than the invasive estimation with subdural electrodes, SEEG can evaluate foci that are deeply seated, noncontiguous leaves, and/or bilateral hemispheres. In addition, SEEG can capture consecutive changes in seizure activity in three dimensions. Due to the development of neuroimaging, computer-assisted, and robotic surgery technology, SEEG insertion began to be commonly used worldwide. Although the approximate complication rates of SEEG are estimated as 1% to 3%, which is lower than that of subdural electrode implantation, the risks of major complications, such as permanent neurological deficit and death, are equivalent. Therefore, meticulous procedure must be needed. To introduce SEEG for intractable partial epilepsy, we acquired approval from the institutional review board and concurrently imported surgical devices and electrodes from the manufacturer in the United States for two surgical candidates. We safely performed SEEG insertion, focal identification, and brain functional mapping by cortical electrical stimulation in two cases. Insertion was difficult for some electrodes, which could be due to the lack of adequate surgical device and large skull angle. Hopefully, the official installation of SEEG will be planned in the near future. We hereby reported tips and pitfalls of SEEG implantation through our own experience in a single institute.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Porin Insertion in the Outer Mitochondrial Membrane
Three models describe the assembly of porins by the SAM complex and their insertion into the outer membrane. Model 1 suggests that porins are assembled outside the SAM channel as the...
Insertion of Single-pass Transmembrane Proteins in the RER
Integral transmembrane proteins possess transmembrane and extra membrane domains. The transmembrane domains are primarily made of 20-25 hydrophobic amino acids arranged in a helical secondary confirmation. These...
Insertion of Multi-pass Transmembrane Proteins in the RER
The multipass transmembrane proteins are the type IV integral membrane proteins with multiple topogenic sequences determining their spatial arrangement in the ER membrane. Nearly all multipass proteins lack a cleavable signal sequence and use...
The Anchoring-and-Adjustment Heuristic

