Microbiologic Analysis of Immediately Loaded Full-Arch Implant-Retained Prosthesis Protocol After 2 Years of Loading:
Purpose:
The All-on-4 treatment concept has been shown to be an effective clinical procedure; however, to date, no studies have analyzed the subgingival microbiota present in these restorations. The purpose of this study was to evaluate the microbial profile of the subgingival biofilm around dental implants placed in the All-on-4 protocol and compare the microbial profile around axial and tilted implants.
Materials And Methods:
Fourteen subjects treated by the All-on-4 concept were evaluated clinically and microbiologically. Subgingival biofilm was collected from each patient, and the amount of 40 species of bacteria was assessed using the checkerboard DNA-DNA hybridization technique.
Results:
The results for the indices of probing depth (PD), bleeding on probing, marginal bleeding, and visible plaque were 2.32 mm, 46%, 60%, and 57%, respectively. Tilted implants presented a significantly higher mean PD and Plaque Index compared with axial implants (P < .05). Fusobacterium nucleatum ssp vincentii, Veillonella parvula, and Fusobacterium nucleatum ssp polymorphum were found in higher levels; however, no difference in the microbial composition was observed between tilted and axial implants (P > .05). Tilted implants presented statistically higher mean levels for the orange complex in relation to the axial implants (P < .05).
Conclusion:
Despite the clinical success rate of the All-on-4 protocol, the subgingival biofilm of tilted implants presented a higher proportion for the orange complex pathogens in comparison to axial implants. These data could suggest that subjects with this modality of implant-supported restoration must be aware that they need a more rigorous maintenance protocol.
More Related Videos
Related Concept Videos
Impact Loading
In cases of elastic deformation,...
Distributed Loads
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
Eccentric Loading
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...


