Simultaneous analysis by LC-MS/MS of 22 ketosteroids with hydroxylamine derivatization and underivatized estradiol
Merja R Häkkinen1, Teemu Murtola2, Raimo Voutilainen3
1School of Pharmacy, University of Eastern Finland, Yliopistonranta 1B, 70210, Kuopio, Finland.
Abstract:
This study describes a validated LC-MS/MS method for assaying 23 steroids within a single run from 150 μl of human plasma, serum or prostatic tissue homogenate. Isotope-labeled steroids were used as internal standards. Samples were extracted with toluene, and ketosteroids were derivatized with hydroxylamine prior to LC-MS/MS analysis. The steroids were separated on a C18 column and methanol was used as an organic solvent with the addition of 0.2 mM ammonium fluoride to improve underivatized estradiol (E2) ionization. Certified reference serums as well as plasma samples, and homogenates of prostate tissue were utilized in the method validation. The specificity of the method was inspected with a total of 27 steroids. The validation proved that the method was suitable for the quantitative analysis of a wide panel of androgens (testosterone, T (3.3 pM-13 nM); androstenedione, A4 (3.3 pM-13 nM); 5α-androstanedione, DHA4 (13 pM-13 nM); dehydroepiandrosterone, DHEA (67 pM-133 nM); dihydrotestosterone, DHT (33 pM-33 nM); 11-ketodihydrotestosterone, 11KDHT (13 pM-13nM); 11-ketotestosterone, 11KT (33 pM-6.7 nM); 11β-hydroxyandrostenedione, 11bOHA4 (33 pM-13 nM); 11β-hydroxytestosterone, 11OHT (13 pM-33 nM)), as well as estrogens (estrone, E1 (3.3 pM-13 nM)), progestagens (17α-hydroxypregnenolone, 17OHP5 (32 pM-127 nM); 17α-hydroxyprogesterone, 17OHP4 (67 pM-133 nM); progesterone, P4 (3.3 pM-13 nM); pregnenolone, P5 (6.6 pM-13 nM)), and glucocorticoids (cortisol, F (33 pM-134 nM); cortisone E (66 pM-131 nM); corticosterone, B (33 pM-67 nM); 11-deoxycortisol, S (33 pM-66 nM); 21-hydroxyprogesterone, 21OHP4 (32 pM-13 nM)). Furthermore, E2 (335 pM-134 nM) and 11α-hydroxyandrostenedione, 11aOHA4 (33 pM-33 nM) could be analyzed if the concentration in the sample was high enough. In addition, aldosterone, A (128 pM-64 nM) and 11-ketoandrostenedione, 11KA4 (33 pM-13 nM) could be analyzed semiquantitatively. The limits of quantification for all compounds ranged from 0.9 to 91 pg/ml, and from 0.009 to 0.9 pg/mg tissue. Compared to our previous method, this new method also permits the analysis of the more challenging steroids, like DHT, DHEA and P5, and a panel of 11-ketosteroids.
More Related Videos
Related Concept Videos
Composition of Blood Plasma
Enlargement of the Plasma Membrane
Serum Laboratory Studies, Stool Test, Breath Test
Serum Studies: Renal Function Tests
Tissues
Plasma Membrane in Bacteria and Archaea