[Opacification of hydrophilic intraocular lens after multiple injections of bevacizumab]
S Roland1, R Khoramnia2, G U Auffarth2
1Augenklinik, Konventhospital der Barmherzigen Brüder Linz, Seilerstätte 2, 4021, Linz, Österreich. sandra.roland@gmx.at.
Abstract:
In the literature various causes of opacification of hydrophilic lenses have been described. Pronounced opacity is a complication that must be taken seriously because it can lead to explantation or exchange of the intraocular lens (IOL). The calcification of hydrophilic IOLs is often made responsible for an explantation. Despite the rapidly increasing number of intravitreal injections, they have so far not been associated with opacification of lenses. This article reports on a female patient where opacification of the hydrophilic lens was obviously associated with multiple intravitreal injections over several years. It involved a secondary calcification with calcium phosphate deposition directly under the surface of the IOL. Possible pathomechanisms are discussed. Due to the increasing number of intravitreal injections the association with IOL opacity should be further evaluated in the future. Generally, with hydrophilic lens materials it must be taken into consideration that these can become opaque following diverse interventions.
Related Concept Videos
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Multiple Allele Traits
Multiple Regression
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Multiple Bar Graph
Each bar or column in the multiple bar graph represents a data value. These graphs are used primarily in interrelating two or more sets of data. The categories of different kinds of data are listed along the horizontal or x-axis, whereas...