Immobilized bacterial biosensor for rapid and effective monitoring of acute toxicity in water
Hendri Wasito1, Amin Fatoni2, Dadan Hermawan3
1Department of Pharmacy, Faculty of Health Sciences, Jenderal Soedirman University, Purwokerto 53123, Indonesia; Biosensory Technology Division, Center for Maritime Biosciences Studies, Jenderal Soedirman University, Purwokerto 53123, Indonesia.
Abstract:
The use of biosensors by using microorganisms such as bacteria have short life cycles and provide other advantages. One colorimetric biosensor technique that has been developed is the use of a biosensor utilizing the incorporation of Prussian blue formation reactions mediated by E. coli bioreactors with ferricyanide. Immobilization is a method that allows the bacteria can be used for long-term without reducing its ability as bioreceptor. This study aimed to develop a novel and rapid immobilized bacterial biosensor for the detection of toxic compound in water and to evaluate their analytical performances. Immobilization of E. coli performed by trapping method using alginate material support. The bacterial suspension was mixed with sodium alginate (1:1 v/v), and the mixture was continuously dropped in CaCl2 solution to be a form of beads. The beads were used as bioreceptor to detect toxicants regarding cadmium, arsenic, mercury, chromium and lead solutions with Prussian blue as a colorimetric indicator. The linearity and sensitivity of detection of beads to the toxicants were tested, the stability of repeated use and storage were evaluated as well. The results showed that E. coli could be immobilized using alginate with response value was correlated with toxic concentration. The developed biosensor was more stable when used repeatedly and could be stored in a long time. The immobilization of E. coli in calcium alginate bead was successfully performed as a biosensor system for monitoring acute toxicity in water.
More Related Videos
Related Concept Videos
Water and Mineral Acquisition
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
The Water Cycle
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
Quality of Water
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...