Online profiling of living rat brain extracellular pH using a pH-Dependent solid phase extraction scheme coupled with
1Department of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung, 20224, Taiwan.
Abstract:
In this study, a novel analytical method was developed for online profiling of living rat brain extracellular pH. It involved microdialysis (MD) sampling, introduction of metal ions (e.g., Mn, Co, Ni, Cd) as acid/base indicators, and a pH-dependent solid phase extraction (SPE) based on polymer-metal ion interactions as a sample pretreatment scheme prior to analysis through inductively coupled plasma mass spectrometry (ICP-MS). With a 10-μL microdialysate, optimization of the system provided a working pH range from 5.8 to 8.2 and allowed differentiation of tiny changes in pH, down to a resolution of 0.015 pH units. Standard deviations of measured pH for 6 h of continuous measurement were below 0.05, which was sufficient for evaluating the homeostatic status and the dynamic fluctuations in living rat brain extracellular pH. The method's applicability was verified through measurement of the basal extracellular pH in living rat brains and through monitoring of its changes in response to perfusion of a high-K+ medium. By applying metal ions as acid/base indicators and coupling a pH-dependent SPE scheme with MD sampling and ICP-MS, this method presents an alternative strategy for reliable online profiling of the living rat brain extracellular pH.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
G-protein Coupled Receptors
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...