Related Experiment Video
Updated: Jan 28, 2026

Dissection of Human Retina and RPE-Choroid for Proteomic Analysis
Published on: November 12, 2017
Analysis of Peripapillary Choroidal Thickness in Unilateral Amblyopia
Gulfidan Bitirgen1, Enver Mirza2, Ahmet Ozkagnici1
1Department of Ophthalmology, Necmettin Erbakan University Meram Faculty of Medicine, Konya, Turkey.
Purpose:
To evaluate the peripapillary choroidal thickness (CT) in children with unilateral amblyopia using spectral-domain optical coherence tomography (SD-OCT).
Methods:
One hundred and six eyes of 53 children with unilateral amblyopia and 20 eyes of 20 children with normal vision were involved in this study. Of the 53 children with unilateral amblyopia, 29 (54.7%) had hyperopic anisometropic amblyopia and 24 (45.3%) had strabismic amblyopia. Peripapillary CT was measured from 6 mm length radial B-scans at the optic nerve head using the enhanced depth imaging program of an SD-OCT (Heidelberg Engineering, Germany). Age, sex, refractive error, and best-corrected visual acuity were also recorded.
Results:
The average peripapillary CT was greater in amblyopic eyes than in the fellow eyes of the children with amblyopia (P = 0.002), and control eyes (P < 0.001). There was no significant difference between the fellow eyes of children with amblyopia and the control eyes (P = 0.158). The average peripapillary CT was negatively correlated with axial length (AL) in amblyopic eyes (r = -0.381; P = 0.005) and fellow eyes (r = -0.392; P = 0.004) but not in control eyes (r = -0.232; P = 0.325). After adjustment for the possible effects of AL, the average peripapillary CT in amblyopic eyes was still greater than in fellow eyes (P = 0.014) and control eyes (P = 0.022).
Conclusion:
The peripapillary choroid of eyes with amblyopia was thicker than that of the fellow eyes and control eyes. No significant difference was observed between fellow eyes and control eyes.
More Related Videos
09:56In Vivo Multimodal Imaging and Analysis of Mouse Laser-Induced Choroidal Neovascularization Model
Published on: January 21, 2018
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
Related Concept Videos
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Qualitative Analysis
For instance, group IV...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Pedigree Analysis
Nodal Analysis
Consider, for instance, a simple circuit composed of three nodes and three resistors, as shown in...