Related Experiment Video
Updated: Jan 28, 2026

Sample Preparation for Endopeptidomic Analysis in Human Cerebrospinal Fluid
Published on: December 4, 2017
THE COMPARATIVE ANALYSIS OF DIFFERENT TECHNIQUES OF LASER POLARIMETRY FOR DETERMINATION OF TIME OF DEATH IN THE STUDY
M Garazdiuk1, O Vanchuliak1, O Garazdiuk1
1Higher State Educational Establishment of Ukraine "Bukovinian State Medical University", Chernivtsi, Ukraine.
Abstract:
The estimation of death coming prescription (DCP) is one of the most important issues that confronts a medical examiner during the corpse examination right at the scene of death. The most promising biological object for the DCP estimation is cerebrospinal fluid. Aim - to compare the effectiveness of methods being used: stokes-polarimetry, stokes-colorimetry, autofluorescence polarimetry in order to improve the accuracy of DCP for the long - and short-term time intervals. The object of the study - cerebrospinal fluid from 75 cadavers (study group) and 20 live individuals (control group). Methods used: stokes polarimetry, stokes-colorimetry, autofluorescence polarimetry. When analyzing the image of the biological sample within the statistical analysis using the stokes polarimetry it is possible to obtain some quantitative characteristics about the amount of the statistical moments of the 1st - 4th orders, which can be used to find the relationship between them and the DCP. However, the coordinate and morphological structure of biological samples are ignored when using this approach. A correlation method in this context is more functional and sensitive. Due to this a higher accuracy of DCP is achieved in a short period. The analysis revealed that the spatial-frequency filtration of polarization-inhomogeneous images of polycrystal films of cerebrospinal fluid improves the time monitoring sensitivity of biochemical changes in optically active molecular compounds. Speaking about fluorescence microscopy - it carries the information about the concentration of molecular complexes of proteins, NADH, flavins, porphyrins, etc. As in the postmortem period the changes in the cerebrospinal fluid begin with the changes in the concentration of biochemical compounds, and crystalline changes are secondary, this method is the most effective for diagnosing the death coming prescription in the first 8 hours. The fluorescent methods of laser polarimetric are precise at a short interval of DCP estimation, and the polarization ones allow us to estimate this parameter at the long-term time intervals, though with less accuracy.
Related Concept Videos
Cerebrospinal Fluid
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
Comparing the Survival Analysis of Two or More Groups
Voltammetric Techniques: Linear-Scan (E vs Time)
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
The Fluid Mosaic Model
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...

