Related Experiment Video
Updated: Jan 26, 2026

Animal Model of Implant-Associated Infections in Mice
Published on: June 27, 2025
Antibiotic-eluting resorbable bone-void filler evaluated in a large animal infection prevention model
Z Ferrell, D W Grainger, K D Sinclair1
1Elute, Inc., 417 Wakara Way, Salt Lake City, UT 84108, USA.sinclairkristof@gmail.com.
Abstract:
Periprosthetic infection in total knee arthroplasty is a difficult-to-treat complication. Current implant revision procedures use non-degradable, antibiotic-loaded bone cement for local antimicrobial delivery. As a permanent foreign body, antibiotic-loaded bone cement is susceptible to bacterial colonisation after antibiotic release. In this first step, of a multi-study approach, an infection prevention model assessed a resorbable, antibiotic-eluting bone-void filler for preventing infection in a large animal model. Four groups of sheep were utilised to monitor antibiotic-eluting bone-void filler-induced osteoconductivity, infection prevention, and implant resorption. Explanted bone and surrounding tissues were evaluated using quantitative microbiology, backscattered electron microscopy, bone mineral apposition, and Sanderson's staining at the 12-week endpoint. Control groups received commercially available bone-void filler, implanted into a surgically created defect on the right medial femoral condyle. Experimental groups received six antibiotic-eluting bone-void filler devices placed into identically sized defects. One control and one experimental group tested osteoconductivity. An additional control and experimental group were each inoculated with 5 × 105 colony forming units/mL Staphylococcus aureus during implant placement for bactericidal effects. Osteoconductivity was confirmed for both antibiotic-eluting bone-void filler and commercially available bone-void filler. The experimental group inoculated with S. aureus showed no detectable bacteria at the study's 12-week endpoint, while infection controls required euthanasia 6-11 d post-inoculation due to infection. This large animal study validated this antibiotic-eluting bone-void filler as osteoconductive, in situ degradable, and bactericidal. All groups, except the infection control, exhibited bone formation comparable to commercial filler ProOsteon®500R.
More Related Videos
09:09Treatment with Vancomycin Loaded Calcium Sulphate and Autogenous Bone in an Improved Rabbit Model of Bone Infection
Published on: March 14, 2019
10:31Surgical Angiogenesis in Porcine Tibial Allotransplantation: A New Large Animal Bone Vascularized Composite Allotransplantation Model
Published on: August 13, 2017
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Additives and Fillers in Concrete
The...
Antibiotic Selection
Models of Health Promotion and Illness Prevention II
The agent-host-environment model states that disease results...
Total Voids in Concrete
Models of Health Promotion and Illness Prevention I
The health belief model (HBM) attempts to predict health-related behavior in specific belief patterns. According to the HBM, a person's...